Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
2.
J Neuroradiol ; 2023 Oct 06.
Article in English | MEDLINE | ID: mdl-37805126

ABSTRACT

INTRODUCTION: Functional magnetic resonance imaging is a powerful tool that has provided many insights into cognitive sciences. Yet, as its analysis is mostly based on the knowledge of an a priori canonical hemodynamic response function (HRF), its reliability in patients' applications has been questioned. There have been reports of neurovascular uncoupling in patients with glioma, but no specific description of the Hemodynamic Response Function (HRF) in glioma has been reported so far. The aim of this work is to describe the HRF in patients with glioma. METHODS: Forty patients were included. MR images were acquired on a 1.5T scanner. Activated clusters were identified using a fuzzy general linear model; HRFs were adjusted with a double-gamma function. Analyses were undertaken considering the tumor grade, age, sex, tumor location, and activated location. RESULTS: Differences are found in the occipital, limbic, insular, and sub-lobar areas, but not in the frontal, temporal, and parietal lobes. The presence of a glioma slows the time-to-peak and onset times by 5.2 and 3.8 % respectively; high-grade gliomas present 8.1 % smaller HRF widths than low-grade gliomas. DISCUSSION AND CONCLUSION: There is significant HRF variation due to the presence of glioma, but the magnitudes of the observed differences are small. Most processing pipelines should be robust enough for this magnitude of variation and little if any impact should be visible on functional maps. The differences that have been observed in the literature between functional mapping obtained with magnetic resonance vs. that obtained with direct electrostimulation during awake surgery are more probably due to the intrinsic difference in the mapping process: fMRI mapping detects all recruited areas while intra-surgical mapping indicates only the areas indispensable for the realization of a certain task. Surgical mapping might not be the gold standard to use when trying to validate the fMRI mapping process.

3.
Neurosurg Focus ; 53(6): E2, 2022 12.
Article in English | MEDLINE | ID: mdl-36455268

ABSTRACT

OBJECTIVE: Noninvasive brain mapping with functional MRI (fMRI) and mapping with direct electrical stimulation (DES) are important tools in glioma surgery, but the evidence is inconclusive regarding the sensitivity and specificity of fMRI. The Human Connectome Project (HCP) proposed a new cortical parcellation that has not been thoroughly tested in a clinical setting. The main goal of this study was to evaluate the correlation of fMRI and DES mapping with HCP areas in a clinical setting, and to evaluate the performance of fMRI mapping in motor and language tasks in patients with glioma, using DES as the gold standard. METHODS: Forty patients with supratentorial gliomas were examined using preoperative fMRI and underwent awake craniotomy with DES. Functional activation maps were visualized on a 3D representation of the cortex, classified according to HCP areas, and compared with surgical mapping. RESULTS: Functional MRI was successful in identifying language and motor HCP areas in most cases, including novel areas such as 55b and the superior longitudinal fasciculus (SLF). Functional MRI had a sensitivity and specificity of 100% and 71%, respectively, for motor function in HCP area 4. Sensitivity and specificity were different according to the area and fMRI protocol; i.e., semantic protocols performed better in Brodmann area (BA) 55b/peri-sylvian language areas with 100% sensitivity and 20% specificity, and word production protocols in BAs 44 and 45 with 70% sensitivity and 80% specificity. Some compensation patterns could be observed, such as motor activation of the postcentral gyrus in precentral gliomas. CONCLUSIONS: HCP areas can be detected in clinical scenarios of glioma surgery. These areas appear relatively stable across patients, but compensation patterns seem to differ, allowing occasional resection of activating areas. Newly described areas such as 55b and SLF can act as critical areas in language networks. Surgical planning should account for these parcellations.


Subject(s)
Connectome , Glioma , Humans , Magnetic Resonance Imaging , Glioma/diagnostic imaging , Glioma/surgery , Nerve Net , Electric Stimulation
4.
Rev. med. Chile ; 150(7): 958-965, jul. 2022. tab, ilus, graf
Article in Spanish | LILACS | ID: biblio-1424148

ABSTRACT

At the beginning of the COVID-19 pandemic in Chile, in March 2020, a projection indicated that a significant group of patients with pneumonia would require admission to an Intensive Care Unit and connection to a mechanical ventilator. Therefore, a paucity of these devices and other supplies was predicted. The initiative "Un respiro para Chile" brought together many people and institutions, public and private. In the course of three months, it allowed the design and building of several ventilatory assistance devices, which could be used in critically ill patients.


Subject(s)
Humans , Pandemics , COVID-19 , Respiration, Artificial , Ventilators, Mechanical , Chile/epidemiology , Intensive Care Units
5.
Front Cell Neurosci ; 16: 866122, 2022.
Article in English | MEDLINE | ID: mdl-35634466

ABSTRACT

Menopause transition can be interpreted as a vulnerable state characterized by estrogen deficiency with detrimental systemic effects as the low-grade chronic inflammation that appears with aging and partly explains age-related disorders as cancer, diabetes mellitus and increased risk of cognitive impairment. Over the course of a lifetime, estrogen produces several beneficial effects in healthy neurological tissues as well as cardioprotective effects, and anti-inflammatory effects. However, clinical evidence on the efficacy of hormone treatment in menopausal women has failed to confirm the benefit reported in observational studies. Unambiguously, enhanced verbal memory is the most robust finding from longitudinal and cross-sectional studies, what merits consideration for future studies aiming to determine estrogen neuroprotective efficacy. Estrogen related brain activity and functional connectivity remain, however, unexplored. In this context, the resting state paradigm may provide valuable information about reproductive aging and hormonal treatment effects, and their relationship with brain imaging of functional connectivity may be key to understand and anticipate estrogen cognitive protective effects. To go in-depth into the molecular and cellular mechanisms underlying rapid-to-long lasting protective effects of estrogen, we will provide a comprehensive review of cognitive tasks used in animal studies to evaluate the effect of hormone treatment on cognitive performance and discuss about the tasks best suited to the demonstration of clinically significant differences in cognitive performance to be applied in human studies. Eventually, we will focus on studies evaluating the DMN activity and responsiveness to pharmacological stimulation in humans.

6.
Front Bioeng Biotechnol ; 10: 819697, 2022.
Article in English | MEDLINE | ID: mdl-35310000

ABSTRACT

Introduction: In Chile, 1 in 8 pregnant women of middle socioeconomic level has gestational diabetes mellitus (GDM), and in general, 5-10% of women with GDM develop type 2 diabetes after giving birth. Recently, various technological tools have emerged to assist patients with GDM to meet glycemic goals and facilitate constant glucose monitoring, making these tasks more straightforward and comfortable. Objective: To evaluate the impact of remote monitoring technologies in assisting patients with GDM to achieve glycemic goals, and know the respective advantages and disadvantages when it comes to reducing risk during pregnancy, both for the mother and her child. Methods: A total of 188 articles were obtained with the keywords "gestational diabetes mellitus," "GDM," "gestational diabetes," added to the evaluation levels associated with "glucose level," "glycemia," "glycemic index," "blood sugar," and the technological proposal to evaluate with "glucometerm" "mobile application," "mobile applications," "technological tools," "telemedicine," "technovigilance," "wearable" published during the period 2016-2021, excluding postpartum studies, from three scientific databases: PUBMED, Scopus and Web of Science. These were managed in the Mendeley platform and classified using the PRISMA method. Results: A total of 28 articles were selected after elimination according to inclusion and exclusion criteria. The main measurement was glycemia and 4 medical devices were found (glucometer: conventional, with an infrared port, with Bluetooth, Smart type and continuous glucose monitor), which together with digital technology allow specific functions through 2 identified digital platforms (mobile applications and online systems). In four articles, the postprandial glucose was lower in the Tele-GDM groups than in the control group. Benefits such as improved glycemic control, increased satisfaction and acceptability, maternal confidence, decreased gestational weight gain, knowledge of GDM, and other relevant aspects were observed. There were also positive comments regarding the optimization of the medical team's time. Conclusion: The present review offers the opportunity to know about the respective advantages and disadvantages of remote monitoring technologies when it comes to reducing risk during pregnancy. GDM centered technology may help to evaluate outcomes and tailor personalized solutions to contribute to women's health. More studies are needed to know the impact on a healthcare system.

7.
Rev Med Chil ; 150(7): 958-965, 2022 Jul.
Article in Spanish | MEDLINE | ID: mdl-37906830

ABSTRACT

At the beginning of the COVID-19 pandemic in Chile, in March 2020, a projection indicated that a significant group of patients with pneumonia would require admission to an Intensive Care Unit and connection to a mechanical ventilator. Therefore, a paucity of these devices and other supplies was predicted. The initiative "Un respiro para Chile" brought together many people and institutions, public and private. In the course of three months, it allowed the design and building of several ventilatory assistance devices, which could be used in critically ill patients.


Subject(s)
COVID-19 , Pandemics , Humans , Chile/epidemiology , Ventilators, Mechanical , Intensive Care Units , Respiration, Artificial
8.
Eur J Radiol ; 144: 109995, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34628310

ABSTRACT

BACKGROUND: The study of muscle health has become more relevant lately, due to global aging and a higher incidence of musculoskeletal pathologies. Current exploration techniques, such as electromyography, do not provide accurate spatial information. OBJECTIVE: The objective of this work is to perform a systematic review of the literature to synthesize the contributions that can offer functional MRI techniques commonly used in neuroimaging, applied to skeletal muscle: Blood Oxygen Level Dependent (BOLD), IntraVoxel Incoherent Motion (IVIM), Arterial Spin Labeling (ASL) and Dynamic Contrast Enhanced (DCE). EVIDENCE ACQUISITION: Web of Science and Medline databases were searched, over the last 10 years, focused on the use of BOLD, ASL, IVIM or DCE in skeletal muscle. EVIDENCE SYNTHESIS: 59 articles were included after applying the selection criteria. 37 studies were performed in healthy subjects, and 22 in patients with different pathologies: in peripheral arterial disease, systemic sclerosis, diabetes, osteoporosis, adolescent idiopathic scoliosis, and dermatomyositis. Reference values in healthy subjects still vary in some cases. CONCLUSION: The studies show the feasibility of implementing functional MRI through BOLD, ASL, IVIM or DCE imaging in several muscles and their possible utility in different pathologies. A synthesis of how to implement such exploration is given here. CLINICAL IMPACT: These four techniques are based on sequences already present in clinical MRI scanners, therefore, their use for functional muscle exploration does not require additional investment. These techniques allow visualization and quantification of parameters associated with the vascular health of the muscles and represent interesting support for musculoskeletal exploration.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Adolescent , Diffusion Magnetic Resonance Imaging , Humans , Motion , Muscle, Skeletal/diagnostic imaging , Spin Labels
10.
Front Bioeng Biotechnol ; 9: 780389, 2021.
Article in English | MEDLINE | ID: mdl-35127665

ABSTRACT

Introduction: Artificial intelligence is widely used in medical field, and machine learning has been increasingly used in health care, prediction, and diagnosis and as a method of determining priority. Machine learning methods have been features of several tools in the fields of obstetrics and childcare. This present review aims to summarize the machine learning techniques to predict perinatal complications. Objective: To identify the applicability and performance of machine learning methods used to identify pregnancy complications. Methods: A total of 98 articles were obtained with the keywords "machine learning," "deep learning," "artificial intelligence," and accordingly as they related to perinatal complications ("complications in pregnancy," "pregnancy complications") from three scientific databases: PubMed, Scopus, and Web of Science. These were managed on the Mendeley platform and classified using the PRISMA method. Results: A total of 31 articles were selected after elimination according to inclusion and exclusion criteria. The features used to predict perinatal complications were primarily electronic medical records (48%), medical images (29%), and biological markers (19%), while 4% were based on other types of features, such as sensors and fetal heart rate. The main perinatal complications considered in the application of machine learning thus far are pre-eclampsia and prematurity. In the 31 studies, a total of sixteen complications were predicted. The main precision metric used is the AUC. The machine learning methods with the best results were the prediction of prematurity from medical images using the support vector machine technique, with an accuracy of 95.7%, and the prediction of neonatal mortality with the XGBoost technique, with 99.7% accuracy. Conclusion: It is important to continue promoting this area of research and promote solutions with multicenter clinical applicability through machine learning to reduce perinatal complications. This systematic review contributes significantly to the specialized literature on artificial intelligence and women's health.

11.
Magn Reson Med Sci ; 19(2): 108-118, 2020 May 01.
Article in English | MEDLINE | ID: mdl-31080210

ABSTRACT

PURPOSE: To compare different q-space reconstruction methods for undersampled diffusion spectrum imaging data. MATERIALS AND METHODS: We compared the quality of three methods: Mean Apparent Propagator (MAP); Compressed Sensing using Identity (CSI) and Compressed Sensing using Dictionary (CSD) with simulated data and in vivo acquisitions. We used retrospective undersampling so that the fully sampled reconstruction could be used as ground truth. We used the normalized mean squared error (NMSE) and the Pearson's correlation coefficient as reconstruction quality indices. Additionally, we evaluated two propagator-based diffusion indices: mean squared displacement and return to zero probability. We also did a visual analysis around the centrum semiovale. RESULTS: All methods had reconstruction errors below 5% with low undersampling factors and with a wide range of noise levels. However, the CSD method had at least 1-2% lower NMSE than the other reconstruction methods at higher noise levels. MAP was the second-best method when using a sufficiently high number of q-space samples. MAP reconstruction showed better propagator-based diffusion indices for in vivo acquisitions. With undersampling factors greater than 4, MAP and CSI have noticeably more reconstruction error than CSD. CONCLUSION: Undersampled data were best reconstructed by means of CSD in simulations and in vivo. MAP was more accurate in the extraction of propagator-based indices, particularly for in vivo data.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods , Humans
12.
Magn Reson Med Sci ; 19(3): 216-226, 2020 Aug 03.
Article in English | MEDLINE | ID: mdl-31611542

ABSTRACT

PURPOSE: Intravoxel incoherent motion (IVIM) analysis has attracted the interest of the clinical community due to its close relationship with microperfusion. Nevertheless, there is no clear reference protocol for its implementation; one of the questions being which b-value distribution to use. This study aimed to stress the importance of the sampling scheme and to show that an optimized b-value distribution decreases the variance associated with IVIM parameters in the brain with respect to a regular distribution in healthy volunteers. METHODS: Ten volunteers were included in this study; images were acquired on a 1.5T MR scanner. Two distributions of 16 b-values were used: one considered 'regular' due to its close association with that used in other studies, and the other considered 'optimized' according to previous studies. IVIM parameters were adjusted according to the bi-exponential model, using two-step method. Analysis was undertaken in ROI defined using in the Automated Anatomical Labeling atlas, and parameters distributions were compared in a total of 832 ROI. RESULTS: Maps with fewer speckles were obtained with the 'optimized' distribution. Coefficients of variation did not change significantly for the estimation of the diffusion coefficient D but decreased by approximately 39% for the pseudo-diffusion coefficient estimation and by 21% for the perfusion fraction. Distributions of adjusted parameters were found significantly different in 50% of the cases for the perfusion fraction, in 80% of the cases for the pseudo-diffusion coefficient and 17% of the cases for the diffusion coefficient. Observations across brain areas show that the range of average values for IVIM parameters is smaller in the 'optimized' case. CONCLUSION: Using an optimized distribution, data are sampled in a way that the IVIM signal decay is better described and less variance is obtained in the fitted parameters. The increased precision gained could help to detect small variations in IVIM parameters.


Subject(s)
Brain/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods , Humans , Movement/physiology
13.
BMC Pediatr ; 19(1): 260, 2019 07 26.
Article in English | MEDLINE | ID: mdl-31349791

ABSTRACT

BACKGROUND: Education and health are crucial topics for public policies as both largely determine the future wellbeing of the society. Currently, several studies recognize that physical activity (PA) benefits brain health in children. However, most of these studies have not been carried out in developing countries or lack the transference into the education field. The Cogni-Action Project is divided into two stages, a cross-sectional study and a crossover-randomized trial. The aim of the first part is to establish the associations of PA, sedentarism, and physical fitness with brain structure and function, cognitive performance and academic achievement in Chilean schoolchildren (10-13 years-old). The aim of the second part is to determinate the acute effects of three PA protocols on neuroelectric indices during a working memory and a reading task. METHODS: PA and sedentarism will be self-reported and objectively-assessed with accelerometers in a representative subsample, whilst physical fitness will be evaluated through the ALPHA fitness test battery. Brain structure and function will be assessed by magnetic resonance imaging (MRI) in a randomized subsample. Cognitive performance will be assessed through the NeuroCognitive Performance Test, and academic achievement by school grades. In the second part 32 adolescents (12-13 year-old) will be cross-over randomized to these condition (i) "Moderate-Intensity Continuous Training" (MICT), (ii) "Cooperative High-Intensity Interval Training" (C-HIIT), and (iii) Sedentary condition. Neuroelectric indices will be measures by electroencephalogram (EEG) and eye-tracking, working memory by n-back task and reading comprehension by a reading task. DISCUSSION: The main strength of this project is that, to our knowledge, this is the first study analysing the potential association of PA, sedentarism, and physical fitness on brain structure and function, cognitive performance, and academic achievement in a developing country, which presents an important sociocultural gap. For this purpose, this project will use advanced technologies in neuroimaging (MRI), electrophysiology (EEG), and eye-tracking, as well as objective and quality measurements of several physical and cognitive health outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03894241 Date of register: March 28, 2019. Retrospectively Registered.


Subject(s)
Academic Success , Brain/physiology , Cognition , Exercise/psychology , Physical Fitness , Accelerometry , Adolescent , Brain/anatomy & histology , Brain/diagnostic imaging , Child , Chile , Cross-Over Studies , Cross-Sectional Studies , Electroencephalography , Female , Humans , Magnetic Resonance Imaging , Male , Sedentary Behavior
14.
J Magn Reson Imaging ; 39(4): 1027-32, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24136653

ABSTRACT

PURPOSE: To measure both transversal relaxation time (T2 ) and diffusion coefficients within a single scan using a multi-shot approach. Both measurements have drawn interest in many applications, especially in skeletal muscle studies, which have short T2 values. Multiple echo single-shot schemes have been proposed to obtain those variables simultaneously within a single scan, resulting in a reduction of the scanning time. However, one problem with those approaches is the associated long echo read-out. Consequently, the minimum achievable echo time tends to be long, limiting the application of these sequences to tissues with relatively long T2 . MATERIALS AND METHODS: To address this problem, we propose to extend the multi-echo sequences using a multi-shot approach, so that to allow shorter echo times. A multi-shot dual-echo EPI sequence with diffusion gradients and echo navigators was modified to include independent diffusion gradients in any of the two echoes. RESULTS: The multi-shot approach allows us to drastically reduce echo times. Results showed a good agreement for the T2 and mean diffusivity measurements with gold standard sequences in phantoms and in vivo data of calf muscles from healthy volunteers. CONCLUSION: A fast and accurate method is proposed to measure T2 and diffusion coefficients simultaneously, tested in vitro and in healthy volunteers.


Subject(s)
Algorithms , Diffusion Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Muscle, Skeletal/anatomy & histology , Signal Processing, Computer-Assisted , Adult , Female , Humans , Leg , Male , Reference Values , Reproducibility of Results , Sensitivity and Specificity
15.
Prenat Diagn ; 32(3): 252-8, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22430723

ABSTRACT

OBJECTIVES: Human tissues are usually studied using a series of two-dimensional visualizations of in vivo or cutout specimens. However, there is no precise anatomical description of some of the processes of human fetal development. The purpose of our study is to develop a quantitative description of the normal axial skeleton by means of high-resolution three-dimensional magnetic resonance (MR) images, collected from six normal 20-week-old human fetuses fixed in formaldehyde. METHODS: Fetuses were collected after spontaneous abortion and subsequently fixed with formalin. They were imaged using a 1.5 T MR scanner with an isotropic spatial resolution of 200 µm. The correct tissue discrimination between ossified and cartilaginous bones was confirmed by comparing the images achieved by MR scans and computerized axial tomographies. The vertebral column was segmented out from each image using a specially developed semi-automatic algorithm. RESULTS: Vertebral body dimensions and inter-vertebral distances were larger in the lumbar region, in agreement with the beginning of the ossification process from the thoracolumbar region toward the sacral and cephalic ends. CONCLUSION: In this article, we demonstrate the feasibility of using MR images to study the ossification process in formalin-fixed fetal tissues. A quantitative description of the ossification centers of vertebral bodies and arches is presented.


Subject(s)
Aborted Fetus/diagnostic imaging , Bone and Bones/diagnostic imaging , Bone and Bones/embryology , Magnetic Resonance Imaging , Osteogenesis/physiology , Pregnancy Trimester, Second , Aborted Fetus/anatomy & histology , Aborted Fetus/drug effects , Aborted Fetus/embryology , Abortion, Spontaneous/diagnostic imaging , Body Patterning/physiology , Bone Density/physiology , Bone and Bones/anatomy & histology , Bone and Bones/physiology , Female , Femur/anatomy & histology , Femur/diagnostic imaging , Formaldehyde/pharmacology , Gestational Age , Humans , Magnetic Resonance Imaging/methods , Male , Organ Size , Pregnancy , Radiography
16.
Rev. chil. radiol ; 18(2): 62-67, 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-647002

ABSTRACT

Objective: Hemodynamic parameters are critical to perform a proper diagnosis. However, due to the large number of variables that can be obtained, overall analysis may represent a complex task. To facilitate this, we propose to create a model for classifying different hemodynamic variables between those belonging to a healthy individual and to a pathological patient. For this purpose, we employed data mining techniques to identify relationships among various aortic hemodynamic parameters obtained through multi-dimensional (4D flow) MR imaging. Method: A 4D flow sequence of whole heart and great vessels was acquired using MRI in 19 healthy volunteers and 2 patients (one with aortic coarctation and one with repaired coarctation of the aorta). Retrospectively, data were reformatted along the aorta; three MRI acquisitions were performed for volunteers and 30 sequences for each patient. In each slice the aorta was segmented and various parameters were quantified: area, maximum velocity, minimum velocity, flow and volumen, with following values being calculated for last four parameters: maximum, average, standard deviation, kurtosis, skewness, proportion of time to reach the maximum value, among others. A total of 26 variables for each acquisition were obtained. In order to classify data, the CART Technique (Classification and Regression Trees) was applied. To validate the model, two extra projections were generated per each volunteer and 20 slice per each patient. Results: By using only 7 variables, the CART Technique allows discrimination between images performed either on volunteers or patients with an error rate of 14.1 percent, a sensitivity of 82.5 percent, and a specificity of 89.4 percent. Conclusions: 4D flow MR imaging provides a wealth of hemodynamic data that can be difficult to analyze. In this paper we demonstrate that by using data mining techniques it is possible to classify images from relevant hemodynamic parameters and their relationships in order...


Objetivo: Los parámetros hemodinámicos son de gran utilidad para realizar un adecuado diagnóstico. Sin embargo, debido a la gran cantidad de variables que pueden obtenerse, el análisis global de todas ellas puede ser complejo. Para facilitar esta tarea, nosotros proponemos crear un modelo que permita clasificar distintas variables hemodinámicas entre las pertenecientes a un individuo sano o a uno patológico. Para ello, usaremos técnicas de minería de datos que permitan identificar y encontrar relaciones entre distintos parámetros hemodinámicos de la aorta obtenidos a través de flujo multidimensional (4D flow) por resonancia magnética. Método: Una secuencia 4D flow de todo el corazón y los grandes vasos fue adquirida utilizando resonancia magnética en 19 voluntarios sanos y 2 pacientes (uno con una coartación aórtica y otro con una coartación aórtica reparada). Retrospectivamente, los datos fueron reformateados a lo largo de la aorta, originándose 3 cortes en los voluntarios y 30 cortes en cada paciente. En cada corte la aorta fue segmentada y distintos parámetros fueron cuantificados: área, velocidad máxima, velocidad mínima, flujo y volumen, calculándose en los cuatro últimos su valor máximo, promedio, desviación estándar, curtosis, sesgo, proporción de tiempo en alcanzar el valor máximo, entre otros. Teniendo un total de 26 variables por cada corte. Se aplicó la técnica de árboles de decisión tipo CART (por sus siglas en inglés) para clasificar los datos. Para validar el modelo, 2 cortes extras fueron generados por cada voluntario y 20 cortes por cada paciente. Resultados: La técnica CART, mediante la utilización de sólo 7 variables, puede clasificar las imágenes de los voluntarios y pacientes con una tasa de error del 14,1 por ciento, una sensibilidad de 82,5 por ciento y una especificidad de 89.4 por ciento. Conclusiones: 4D flow provee una gran cantidad de datos hemodinámicos que son difíciles de analizar. En este trabajo demostramos que al utilizar...


Subject(s)
Humans , Aorta/physiopathology , Cardiac Imaging Techniques , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Blood Flow Velocity/physiology , Image Enhancement/methods , Data Mining , Decision Trees , Cardiovascular Diseases/diagnosis , Hemodynamics , Regional Blood Flow , Regression Analysis , Reproducibility of Results , Sensitivity and Specificity
17.
Rev. chil. radiol ; 16(2): 64-69, 2010. ilus
Article in Spanish | LILACS | ID: lil-577493

ABSTRACT

This study aimed at implementing a stimulation protocol using functional Magnetic Resonance Imaging (fMRI), in a Hospital in Valparaiso (V Region), Chile, to detect cortical areas activated in oral language comprehension. Seven healthy volunteers participated in this study. Average t-score and signal variation were 6.3 +/- 0.3 and 0.5 +/- 0.1 percent, respectively. In spite of these low values, activations were obtained in Wernicke area, middle temporal gyrus, and Heschl s gyrus. The extension of activated areas was small, 5.06 +/- 2.99 cm3, probably due to amplifer low signal-to-noise ratio (SNR), in addition to the cognitive complexity of the task, and to the ambient acoustic noise. Successful implementation of fMRI protocols of language comprehension is possible in a clinical context in Chile without any additional resources.


Nuestro objetivo fue implementar un protocolo de estimulación en resonancia magnética funcional en un Hospital de Valparaíso, V Región de Chile, para detectar las áreas corticales activadas en la comprensión del lenguaje oral. Siete voluntarios sanos participaron de este estudio. El t-score y variación de señal alcanzado fue de 6.3 0.3 y 0.5 +/- 0.1 por ciento respectivamente. A pesar de estos bajos valores, las activaciones se registraron en el área Wernicke, circunvolución temporal media y circunvolución d e Heschl. La extensión de las activaciones fue pequeña, 5.06 +/- 2.99 cm³, probablemente debido a la baja relación señal ruido del resonador (SNR), además de la complejidad cognitiva de la tarea y el ruido acústico ambiente. Nuestros resultados indican que la implementación de la RMf en comprensión del lenguaje es posible de realizar en Chile sin recursos adicionales.


Subject(s)
Humans , Male , Female , Cerebrum/physiology , Comprehension/physiology , Physical Stimulation/methods , Speech/physiology , Magnetic Resonance Imaging/methods
18.
Biol Res ; 40(4): 385-400, 2007.
Article in English | MEDLINE | ID: mdl-18575674

ABSTRACT

Diffusion Magnetic Resonance Imaging provides images of unquestionable diagnostic value. It is commonly used in the assessment of stroke and in white matter fiber tracking, among other applications. The diffusion coefficient has been shown to depend on cell concentration, membrane permeability, and cell orientation in the case of white matter or muscle fiber tracking; yet a clear relation between diffusion measurements and known physiological parameters is not established. The aim of this paper is to review hypotheses and actual knowledge on diffusion signal origin to provide assistance in the interpretation of diffusion MR images. Focus will be set on brain images, as most common applications of diffusion MRI are found in neuroradiology. Diffusion signal does not come from two intra- or extracellular compartments, as was first assumed. Restriction of water displacement due to membranes, hindrance in the extracellular space, and tissue heterogeneity are important factors. Unanswered questions remain on how to deal with tissue heterogeneity, and how to retrieve parameters less troublesome to work with from biological and clinical points of view. Diffusion quantification should be done with care, as many variables can lead to variation in measurements.


Subject(s)
Brain/physiology , Diffusion Magnetic Resonance Imaging , Anisotropy , Humans , Models, Biological
19.
Biol. Res ; 40(4): 385-400, 2007. ilus, tab, graf
Article in English | LILACS | ID: lil-484867

ABSTRACT

Diffusion Magnetic Resonance Imaging provides images of unquestionable diagnostic value. It is commonly used in the assessment of stroke and in white matter fiber tracking, among other applications. The diffusion coefficient has been shown to depend on cell concentration, membrane permeability, and cell orientation in the case of white matter or muscle fiber tracking; yet a clear relation between diffusion measurements and known physiological parameters is not established. The aim of this paper is to review hypotheses and actual knowledge on diffusion signal origin to provide assistance in the interpretation of diffusion MR images. Focus will be set on brain images, as most common applications of diffusion MRI are found in neuroradiology. Diffusion signal does not come from two intra- or extracellular compartments, as was first assumed. Restriction of water displacement due to membranes, hindrance in the extracellular space, and tissue heterogeneity are important factors. Unanswered questions remain on how to deal with tissue heterogeneity, and how to retrieve parameters less troublesome to work with from biological and clinical points of view. Diffusion quantification should be done with care, as many variables can lead to variation in measurements.


Subject(s)
Humans , Brain/physiology , Diffusion Magnetic Resonance Imaging , Anisotropy , Models, Biological
20.
J Magn Reson Imaging ; 22(2): 307-10, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16028249

ABSTRACT

PURPOSE: To investigate the diffusion tensor properties of the human optic nerve in vivo using a non-Carr-Purcell-Meiboom-Gill (CPMG) fast spin echo (FSE) sequence. MATERIALS AND METHODS: This non-CPMG FSE sequence, which is based on a quadratic phase modulation of the refocusing pulses, allows diffusion measures to be acquired with full signal and without artifacts from geometric distortions due to magnetic field inhomogeneities, which are among the main problems encountered in the orbital area. RESULTS: Good-quality images were obtained at a resolution of 0.94 x 0.94 x 3 mm. The mean diffusivity (MD) and fractional anisotropy (FA) were respectively 1.1 +/- 0.2 x 10(-3) mm(2)/second and 0.49 +/- 0.06, reflecting the optic nerve anisotropy. CONCLUSION: This non-CPMG-FSE sequence provides reliable diffusion-weighted images of the human optic nerve. This approach could potentially improve the diagnosis and management of optic nerve diseases or compression, such as optic neuritis, orbit tumors, and muscle hypertrophy.


Subject(s)
Algorithms , Echo-Planar Imaging/methods , Optic Nerve/pathology , Artifacts , Cohort Studies , Female , Humans , Male , Optic Nerve/anatomy & histology , Phantoms, Imaging , Reference Values , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...